AMT569 Transmitted Spectrophotometer

AMT569 Transmitted Spectrophotometer

Features:
●instrument uses globally accepted D/0(integrating sphere diffused lighting, 0 degrees observer),both SCI and SCE included lighting and observation conditions.
●use CLEDs light source-LED light source that has balanced intensity across visible spectrum deficiency in certain parts of the spectrum in common white LEDs, and guarantees the speed of the measurement and the accuracy of the measurement results.
●it uses innovative ETC(Every Test Calibration);standard white board is included in the optical system, and therefore has reliable accuracy and repeatability in every measurement

●SCS optical engine, creates the best measurement repeatability for spectrophotometers in the industry, and guaranteed accurate measurement of surface color of materials.

Specifications:
Model AMT569
Illumination d/0(Diffused lighting, 0 degrees observe angle)SCS optical engine(light splitting and integration system),ETC(real time calibration technology, SCI(specular reflection included)/SCE(specular reflection excluded)simultaneous measurement。(conform to CIE No.15、ISO 7724/1、ASTM E1164、DIN 5033 Teil7、 JIS Z8722 Condition c standards)
Size of integrating sphere Φ40mm,Alvan diffused reflection surface coating
Illumination Light source CLEDs(entire wavelength balanced LED light source)
Sensor dual light path sensor array
Wavelength range 400-700nm
Wavelength interval 10nm
Half spectral width 5nm
Reflectivity range 0-200%
Reflectivity resolution 0.00%
Observation angle 2°/10°
Measurement light source A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Data being displayed SPD distribution/data,sample’s color values,color difference values/graph,pass/fail results,color error tendency,color simulation,display measurement area,history data color simulation,manual input standard sample,generate measurement report
Measurement time interval 2 seconds
Measurement time 0.5 seconds
Color space CIE-L*a*b,L*C*h,CIE-L*u*v,XYZ,Yxy,Transmittance
Color difference formulas ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00
Other colorimetric indices WI(ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Ganz, Stensby),YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00,CIE,Ganz),Metamerism index Milm, Stick color fastness, Color fastness,APHA, Pt-Co, Gardner, Seybold
Repeatability light splitting reflectivity:standard deviation within 0.08%color values:ΔE*ab<=0.015(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03
Interface USB
Data storage mass storage
Light source longevity 5 years, 1.5 million tests
Size 475*340*150mm(L*W*H)
Weight about 7kg
Work temperature range 0~45℃, relative humidity 80% or below( at 35°C ),no condensation
Storage temperature range 25℃ to 55℃,relative humidity 80% or below(at 35°C ), no condensation
Standard accessories Power cord, Color management software, Driver software, Data line, Black calibration tube, cell holder
X