With a fixed 50V DC power supply and a current limit of 5mA, the negative terminal is mounted on a stainless steel grounding plate. The test subject wears clean 100% cotton socks and antistatic dissipative shoes. After 5 minutes, the outsole is wiped with a damp cloth of ethanol or isopropanol. The test subject then stands on the stainless steel ground plate and holds the positive electrode handle (connecting the power supply, resistor, electrode, human subject, and sample in series) to perform the test. The sampling voltage drop and the resistance value of the antistatic dissipative shoes are recorded.
Suitable for a wide range of static dissipative shoes, with applications including different models and materials of footwear.
The resistance of the static dissipative shoes must be less than 100,000Ω; tests will not be conducted if the resistance exceeds this value.
Using a fixed power supply and detailed test procedures to ensure the standardization of the testing process helps improve repeatability and comparability.
The negative electrode is mounted on a stainless steel grounding plate, which helps ensure operator safety during testing.
During the production process, measures are taken to ensure that the manufactured static dissipative shoes meet relevant antistatic performance standards and specifications in order to improve product quality.
This is used to ensure that static dissipative shoes meet the antistatic performance requirements of relevant regulations and industry standards, thereby ensuring product compliance.
This ensures that products comply with relevant industry standards and regulations, reducing risks and improving market compliance.
The primary purpose of an antistatic tester is to evaluate the performance of antistatic dissipative shoes, ensuring they meet applicable standards and specifications. By simulating real-world usage environments, this test provides a quantitative assessment of the antistatic performance of antistatic dissipative shoes. It is an important tool in manufacturing, quality control, compliance testing, and R&D, helping to ensure that the performance of antistatic dissipative shoes meets relevant standards and requirements.
If you have any further questions or needs regarding antistatic testers or other related equipment, please feel free to contact us.
We are dedicated to providing you with professional support and solutions.
With an intuitive and easy-to-use touchscreen interface, users can easily set test parameters and control the machine, improving the ease of operation.
The tester provides a fixed 50V DC power supply and current limit to ensure the accuracy of test results.
It has automation capabilities, which improves testing efficiency and reduces the subjective influence of operators.
| Voltage | DC50V |
| voltage accuracy | 0.001V |
| Volume (W×D×H) | Control box: 250 mm × 240 mm × 200 mm; Stainless steel grounding plate: 400 mm × 400 mm × 2 mm |
| power supply | 1∮ AC 220V 50HZ (depending on country or specific requirements) |