GOTECH Anti-Static Electrical Instrument (GT-3453)

Detail

PRINCIPLE

The GT-3453 is capable of measuring the resistance of soles, outsoles, and finished shoes to provide insights into their anti-static properties.

Multiple test methods:

Offers testing methods for finished shoes, soles, and outsoles to meet different needs in anti-static performance evaluation.

Finished shoe testing:

After filling the footwear specimen with metal spheres to a depth of about 30mm, position the specimen in the water tray, and then connect the red lead to the metal spheres inside the footwear and the black lead to the metal base.

Sole testing:

Position the sole specimen in the water tray and place the L-shaped fixture over it. Mount a 4kg test weight on the fixture, and then connect the red lead to the fixture and the black lead to the metal base.

Outsole testing:

Position the outsole specimen on a metal plate and place the L-shaped fixture over it. Mount a 4kg test weight on the fixture, and then connect the red lead to the fixture and the black lead to the metal base.

Precise voltage setup:

Allows operators to easily adjust output voltage through the user-friendly interface to achieve various testing requirements.

Auto-display of test results:

Displays test results of insulation resistance automatically on the display upon test completion.

Standard conformity:

Ensures that products meet industry standards and satisfy quality expectations in the market.

 

Feature

Comprehensive testing capability

Capable of testing the anti-static performance of soles, outsoles, and finished shoes, providing comprehensive testing capabilities.

High precision

Offers adjustable output voltage to meet various testing requirements, providing precise measurements and accurate test results.

Real-time results display

Displays test results directly, enabling rapid assessment of footwear resistance.

 

Specification

Rated output voltage (DC) 50 V 125 V 250 V 500 V 1,000 V
Effective maximum indicated value 100 MΩ 250 MΩ 500 MΩ 2,000 MΩ 4,000 MΩ
Center scale reading 2 MΩ 5 MΩ 10 MΩ 50 MΩ 100 MΩ
1st effective measuring range [MΩ] 0.200 to 10.00 0.200 to 25.0 0.200 to 50.0 0.200 to 500 0.200 to 1,000
Accuracy ±4% rdg.
2nd effective measuring range [MΩ] 10.1 to 100.0 25.1 to 250 50.1 to 500 501 to 2,000 1,010 to 4,000
Accuracy ±8% rdg.
Other measuring range  [MΩ] 0 to 0.199
Accuracy ±2% rdg. ±6 dgt.
Lower limit resistance 0.05 MΩ 0.125 MΩ 0.25 MΩ 0.5 MΩ 1 MΩ
Overload protection AC 600V 10s AC 1200V 10s
Display LCD with back lighting and bar-graph indicator
Response time 0.6 seconds
Functions Live circuit indicator, automatic electric discharge, automatic DC/AC detection
Dimensions (W×D×H) 190×200×170 (mm)